A flash point tester is an instrument that determines the flash point of a sample, which is the temperature point at which the sample vaporizes to another composition state in the air that can be ignited. At that moment, the flash point apparatus can determine and measure the vapor pressure change in which this occurs, also known as the lowest limit of flammability. Therefore, vapor concentration can be determined by temperature. There are two main types of flash point analyzers: open cup flash point testers and closed cup flashpoint testers. The open type is intended to simulate an open and natural environment, whereas a closed type is more commonly used in laboratory testing.
Applications for flash point testing
Determination of flash point is useful for a variety of applications, such as determining the flash point of diesel and other fuel types in petrochemical analysis, flavors in food testing, paints in materials testing, and waste removal for environmental analysis.
Key considerations for purchasing a flash point tester
When looking to purchase a flash point tester keep a look out for the type, measuring temperature range for sample analysis, and standard method accreditations. Other helpful variables to keep in mind include the minimum sample volume, analysis time, and the capability for autosampling, which allows for more than just one analysis to take place at a time.
Get Quote for All
Select up to 5 products from below to compare or request more information.
eralytics GmbH
- (Modified) Continuously Closed Cup
- ASTM D6450, ASTM D7094 Pre-Programmed Correlation Methods to: Pensky Martens Closed Cup: ASTM D93, EN ISO 2719, DIN 51758, IP 34, JIS K2265, TAG Closed Cup: ASTM D56, Abel Pensky Closed Cup: ISO 13736, IP 170, Small Scale Closed Cup and Flash / No Flash methods: EN ISO 3679, EN ISO 3680, ASTM D3828, IP620
- -25°C to 420°C
eralytics GmbH
- (Modified) Continuously Closed Cup
- ASTM D6450, ASTM D7094
correlation to: ASTM D56, D93, D3828, EN 2719, EN 3679, EN 3680 - -40°C to 120°C
eralytics GmbH
- (Modified) Continuously Closed Cup
- ASTM D6450, ASTM D7094 Pre-Programmed Correlation Methods to: Pensky Martens Closed Cup: ASTM D93, EN ISO 2719, DIN 51758, IP 34, JIS K2265, TAG Closed Cup: ASTM D56, Abel Pensky Closed Cup: ISO 13736, IP 170, Small Scale Closed Cup and Flash / No Flash methods: EN ISO 3679, EN ISO 3680, ASTM D3828, IP620
- -25°C to 420°C
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags
- Reliable and Safer Flash Point Tester
eralytics GmbH
The ERAFLASH Flash Point Tester from eralytics GmbH is a very safe instrument for determining the flash point. We are using this machine for determining the various liquid flashpoints like diesel, ... Read Review